BioTechnosis-37 Fully Automated Clinical Chemistry Analyzer

admin
December 26, 2025

Views: 7

Fully Automated Clinical Chemistry Analyzer

Biotechnosis-37K is an automated clinical chemistry analyzer designed to meet the needs of clinical laboratories with high accuracy, stable throughput, and efficient operation. This instrument is suitable for hospitals, clinics, and diagnostic laboratories that require reliable performance for both routine and advanced testing.

Performance

Fitur Utama

  • Fully Automated System
    Proses analisis berjalan otomatis.

  • Throughput Tinggi & Stabil
    Kecepatan pemeriksaan 300 test per jam.

  • High Precision Optical System
    Sistem optik yang presisi tinggi.

  • Automatic Sample & Reagent Loading
    49 Sample posisi, 56 Reagen.

  • 120 Reusable Reaction Cuvettes
    Mendukung penghematan biaya operasional.

  • User-Friendly Software Interface
    Antarmuka perangkat lunak intuitif, mudah dioperasikan.

Spesifications

Sample & Reagent Needle

Equipped with liquid level detection sensors, Teflon-coated to reduce cross-contamination, anti-collision protection, and automatic position reset.

Reaction Cuvettes :120 reusable reaction cuvettes.

High Precision Optical System : A high-precision optical system ensures accurate and consistent test results.

Sample & Reagent Tray Capacity

Sample Tray: 49 positions, Reagent Tray: 56 positions

Equipped with a 24-hour refrigeration system to ensure reagents remain stable and safe.

Automatic Washing System

An automatic reaction cuvette washing system that ensures cross-contamination (carryover) does not occur between tests, maintaining accurate and consistent analysis results.

Assay Testing

Test Parameters

Biotechnosis-37K supports a wide range of clinical chemistry parameters, including:

  • Liver function

  • Kidney function

  • Metabolic parameters

  • Enzymes and other parameters
    (depending on the methods and reagents used)

Reagent Compatibility

Compatibility: Supports a wide range of commercial reagents, calibrators, and controls (open system).

Dimensions

Environmental Requirements

  • Operating Temperature: 15 โ€“ 30 ยฐC

  • Humidity: 40 โ€“ 85 %

  • Power Supply: 220 V AC / 300 VA

Dimensions & Weight

  • External Dimensions (L ร— W ร— H): 950 ร— 600 ร— 515 mm

  • Net Weight: 75 kg

  • Package Dimensions (L ร— W ร— H): 1130 ร— 735 ร— 1040 mm

  • Gross Weight: 130 kg

Installations & Support

Installation & Support

  • Installation and commissioning by Sintechโ€™s technical team

  • Operator training

  • Service & maintenance support

Documentation

Compliance & Documentation

  • Designed in accordance with medical device safety and quality principles

  • Supports technical documentation and audit requirements

More Information
For final specification details, system configuration, or technical consultation, please contact our team via the Technical Support page.

Benefits for Laboratories

  • Increases analyst productivity

  • Reduces manual errors

  • More efficient operational costs

  • Suitable for both growing and established laboratories

Information & Quotation

For further technical information or pricing inquiries, please contact the PT. Sintech Manunggal Sejahtera team.

SintechDX Technology for Better Healthcare

ย 

โ†Previous
Nextโ†’

Related categories

  • Our Portofolio
    December 28, 2025
  • BioTechnosis Multi Calibrator Reagent
    December 27, 2025
  • BioTechnosis Quality Control Reagents
    December 27, 2025
  • Wastewater Treatment System โ€“ SINTECH Membrane Bioreactor (MBR)
    December 26, 2025
  • BioTechnosis- Quality Control reagents
    December 26, 2025
  • BioTechnosis-48K Fully Automatic Biochemistry Analyzer
    December 26, 2025

Gallery

Pages

Home

About Us

Product & Solutions

Service

Informations

Shipping Policy

Returns & Funds

Cookies Policy

Frequently asked

Links

FAQ

Request a Quote

Technical Support

Contact Us

Powered by
...
►
Necessary cookies enable essential site features like secure log-ins and consent preference adjustments. They do not store personal data.
None
►
Functional cookies support features like content sharing on social media, collecting feedback, and enabling third-party tools.
None
►
Analytical cookies track visitor interactions, providing insights on metrics like visitor count, bounce rate, and traffic sources.
None
►
Advertisement cookies deliver personalized ads based on your previous visits and analyze the effectiveness of ad campaigns.
None
►
Unclassified cookies are cookies that we are in the process of classifying, together with the providers of individual cookies.
None
Powered by